{"product_id":"caldaia-a-gas-ferroli-bluehelix-tech-35c-a-condensazione-metano-completa-di-kit-per-scarico-fumi-erp","title":"FERROLI BLUEHELIX TECH 35C METHANE CONDENSING GAS BOILER COMPLETE WITH SMOKE EXHAUST KIT - ErP Split smoke kit","description":"\u003cp\u003e Overview\u003c\/p\u003e\n\u003cp\u003e FERROLI BLUEHELIX TECH 35C CONDENSING BOILER COMPLETE WITH SMOKE EXHAUST KIT - NEW ErP 2015: Wall-mounted condensing boilers, premixed with sealed chamber with instant DHW production with double exchanger.\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e \u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003eIN THE ABSENCE OF THE PRODUCT THE NEW BLUEHELIX RRT C 34 MODEL WILL BE SUPPLIED, viewable at this link:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003cspan style=\"color: #0000ff;\"\u003ehttps:\/\/www.climaconvenienza.it\/it\/caldaia-a-gas-ferroli-bluehelix-tech-rrt-34c-metano-o-gpl-complete-di-kit-scarico-fumi-new\/\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e Technical specifications\u003c\/p\u003e \u003cp\u003eEnergy label specifications according to the European ErP directive\u003c\/p\u003e\n\u003cp\u003e Class A heating energy efficiency\u003c\/p\u003e\n\u003cp\u003e Energy efficiency sanitarywareprofilXXL Class A\u003c\/p\u003e\n\u003cp\u003e Characteristics of heating\/sanitary operations:\u003c\/p\u003e\n\u003cp\u003e Sealed chamber condensing boiler\u003c\/p\u003e\n\u003cp\u003e Thermal input (PCI)ÿMax Heating: 32 kW\u003c\/p\u003e\n\u003cp\u003e Thermal input (PCI)ÿMax Sanitary: 34.8 kW\u003c\/p\u003e\n\u003cp\u003e Thermal power 80øC-60øCÿMax Heating:ÿ31.4 kW\u003c\/p\u003e\n\u003cp\u003e Thermal power 80øC-60øCÿMax Sanitary:ÿ34.1 kW\u003c\/p\u003e\n\u003cp\u003e Thermic useful efficiencyÿ80øC-60øC: 98%\u003c\/p\u003e\n\u003cp\u003e Thermal efficiencyÿ50øC-30øC: 106.1%\u003c\/p\u003e\n\u003cp\u003e Thermal efficiencyÿCharicridott30%: 108.8%\u003c\/p\u003e\n\u003cp\u003e Domestic hot water production at 30øC: 16.3 l\/min\u003c\/p\u003e\n\u003cp\u003e Domestic hot water production at 25øC: 19.5 l\/min\u003c\/p\u003e\n\u003cp\u003e Energy certification (92\/42 EEC): ****\u003c\/p\u003e\n\u003cp\u003e Protection degrees: IPX5D\u003c\/p\u003e\n\u003cp\u003e Extremely compact dimensions (hxwxd): 600 x 400 x 320 mm; 31kg\u003c\/p\u003e\n\u003cp\u003e Fuel: METHANE\u003c\/p\u003e\n\u003cp\u003e List features\u003c\/p\u003e\n\u003cp\u003e BLUEHELIX TECH\u003c\/p\u003e\n\u003cp\u003e Wall-mounted condensing boilers, premixed with sealed chamber with instant DHW production\u003c\/p\u003e \u003cp\u003eNew series of compact wall-mounted condensing boilers with instant domestic hot water production. Designed to guarantee maximum energy efficiency in heating and in the supply of domestic hot water, thanks to the new patented bivalent exchanger in AISI 316 TI stainless steel. This new exchanger integrates the heating circuit and the production of domestic hot water into a single element, maximizing the condensation phenomenon.\u003c\/p\u003e\n\u003cp\u003e Built to be able to be installed outdoors in partially protected places and equipped with electronics capable of integrating with a solar panel system.\u003c\/p\u003e\n\u003cp\u003e The range:\u003c\/p\u003e\n\u003cp\u003e Range consisting of two models, 27 and 35 kW respectively, running on methane, LPG and propane air.\u003c\/p\u003e\n\u003cp\u003e Strengths:\u003c\/p\u003e\n\u003cp\u003e Boiler body with high performance monothermal primary exchanger in patented AISI 316 TI stainless steel\u003c\/p\u003e\n\u003cp\u003e Instant production of domestic hot water with dedicated domestic plate exchanger\u003c\/p\u003e\n\u003cp\u003e Total premix burner in stainless steel\u003c\/p\u003e \u003cp\u003eDigital control panel\u003c\/p\u003e\n\u003cp\u003e Electronic flame modulation in both heating and domestic hot water\u003c\/p\u003e\n\u003cp\u003e Can be combined with the modulating remote control\u003c\/p\u003e\n\u003cp\u003e Large, multifunction, backlit graphic display for easy and correct parameter setting\u003c\/p\u003e\n\u003cp\u003e Standard by-pass\u003c\/p\u003e\n\u003cp\u003e Refined design, compact dimensions\u003c\/p\u003e\n\u003cp\u003e Casing painted white for anaphoresis with epoxy powders\u003c\/p\u003e\n\u003cp\u003e Advantages :\u003c\/p\u003e\n\u003cp\u003e ECO function in sanitary fixtures for greater savings in periods of low use of hot water\u003c\/p\u003e\n\u003cp\u003e 3-star certified comfort in sanitary production according to EN 13203\u003c\/p\u003e\n\u003cp\u003e Sliding temperature operation via optional external probe\u003c\/p\u003e \u003cp\u003eLow consumption modulating heating circulator (Erp Ready - Class A): Regulation 622\/2012 requires that all boilers placed on the market from 1st August 2015 be equipped with a low consumption circulator, otherwise defined as class A. This is a decision that starts from the consideration of the enormous energy expenditure of the pumps and circulators installed in the various applications. In practice, by overanalyzing the impact of the low consumption circulator integrated into the boiler, it reduces a final 30% of the total electricity consumption of the generator.\u003c\/p\u003e\n\u003cp\u003e Digital flame control with three re-ignition attempts in case of functioning block due to lack of flame detection (methane model)\u003c\/p\u003e\n\u003cp\u003e Preparation for solar systems: predisposed for the production of domestic hot water combined with solar panel systems\u003c\/p\u003e\n\u003cp\u003e Installation location: also for outdoors in partially protected locations down to -5øC as standard and down to -15øC with the aid of the optional antifreeze heater kit\u003c\/p\u003e \u003cp\u003eCertified operation also with propane air (50% air - 50% G31) through specific transformation to be requested from the Authorized Assistance Center\u003c\/p\u003e\n\u003cp\u003e Appliance belonging to class 5, the most environmentally friendly required by European standards (UNI EN 297 NOX and 483)\u003c\/p\u003e\n\u003cp\u003e Products that fall within the tax breaks provided for by the Finance Law in force\u003c\/p\u003e\n\u003cp\u003e Functions:\u003c\/p\u003e\n\u003cp\u003e ECO-COMFORT function: In COMFORT mode, thanks to the particular temperature maintenance system of the heat exchanger, the supply of domestic hot water becomes even quicker and more comfortable. In ECO operation, domestic hot water production occurs according to traditional standards.\u003c\/p\u003e \u003cp\u003eSliding temperature operation:ÿWith the installation of the kit or external probe? It is possible to operate the boiler at a sliding temperature. This means that without acting on the system temperature adjustment buttons, the boiler will self-regulate based on variations in external temperatures. All this translates into energy savings while guaranteeing maximum comfort for the user.\u003c\/p\u003e\n\u003cp\u003e Antifreeze function: In the event that the temperature in the boiler drops to 5øC, the burner automatically turns on and the circulator is activated in order to protect the appliance from damage caused by frost. This function is active with the boiler powered by the circuit gas and electrical sub-voltage.\u003c\/p\u003e \u003cp\u003eSun Easy function: BLUEHELIX TECH was designed to be easily inserted into systems created with the latest technologies. The SUN EASY system, standard on the boiler, uses electronics that simplifies the combination with both natural and forced circulation solar panels. Using a sensor on the sanitary circuit, it continuously controls the temperature of the water coming from the solar panels, providing for the ignition of the burner only when the latter drops to the level necessary to guarantee optimal comfort for the user.\u003c\/p\u003e\n\u003cp\u003e Tangible facts:\u003c\/p\u003e \u003cp\u003eRegulation 622\/2012 requires that all boilers placed on the market from 1 August 2015 be equipped with a low-consumption circulator, otherwise defined as class A. This is a decision that starts from consideration of the enormous energy expenditure of the pumps and circulators installed in the various applications. In practice, by overanalyzing the impact of the low consumption circulator integrated into the boiler, it reduces a final 30% of the total electricity consumption of the generator.\u003c\/p\u003e\n\u003cp\u003e Consummax. standard non-modulating circulator:ÿ0.085 kWÿ\u003c\/p\u003e\n\u003cp\u003e Consummax. new high efficiency circulator:ÿ0.04 kWÿ\u003c\/p\u003e\n\u003cp\u003e Degree daysÿ2500ÿ(average climate band E)ÿ\u003c\/p\u003e\n\u003cp\u003e Energy cost:ÿ0.19 ??¶\/kWhÿ\u003c\/p\u003e\n\u003cp\u003e Hypothetical annual expense max standard circulator speed: ÿ40,375 ??¶ÿ\u003c\/p\u003e\n\u003cp\u003e Hypothetical annual expense max high efficiency circulator speed: ÿ11.4 ??¶ÿ\u003c\/p\u003e \u003cp\u003eTherefore, by replacing standard boilers with Bluehelix Pro, in line with the new ERP regulations, electricity savings of around 30% can be estimated. The savings will actually be even greater, as these are modulating circulators, which at minimum power can achieve consumption of just 3 W\u003c\/p\u003e\n\u003cp\u003e ERP\u003c\/p\u003e\n\u003cp\u003e The new European regulations for heat generatorsÿ\u003c\/p\u003e \u003cp\u003eThe 4 ErP Regulations on: \"Ecodesign\" (minimum efficiency limits) and Energy Labeling (informative energy label) are mandatory European provisions automatically in force from 26 September 2015 simultaneously in the 28 EU countries and in all EEA countries (European Economic Spaces: Liechtenstein, Switzerland, Norway, Iceland). The Regulations (or EU Regulation? nr.: 811\/2013, 812\/2013, 813\/2013 and 814\/2013) are already published by the EU and are legal provisions that leave no legislative power (of modification\/variation of delayed adoption) to EU Member States, as they do not require any national adoption law, but come into force automatically or by themselves? throughout Europe.ÿ\u003c\/p\u003e \u003cp\u003eFrom 26 September 2015, it will no longer be possible to leave the factories and warehouses of the MANUFACTURERS (or the warehouses of IMPORTERS from outside the EU) compliant boilers, heat pumps, tanks\/kettles, water heaters or non-ErP compliant systems, except for products for which this has already been carried out. the placing on the market or the formal transfer of ownership (before 26 September) to the first customer\/distributor of the commercial chain. The date which is authentic is the date of first placing on the market of the finished product. In practice, by virtue of the new Regulations, manufacturers in the EU area and importers from outside the EU will be obliged to offer for sale only highly efficient products and systems, both for space heating and for the preparation of domestic hot water. Will the end customer be able to immediately find latest generation products on the market? which will be mandatorily accompanied by an ENERGY LABEL and compliant with the MINIMUM LIMITS calculated according to rigorous European standards which for the first time for these new products or ErP? consider all types of direct and indirect consumption of the appliances, e.g.: gas consumption and electricity consumption in a boiler.ÿ\u003c\/p\u003e \u003cp\u003eNew ErP efficiency limits (and noise limits for heat pumps only) will apply to heating systems (boilers and heat pumps) up to 400 kW, to instantaneous gas and electric water heater systems up to 400 kW, to DHW tanks up to 2,000 lt.\u003c\/p\u003e\n\u003cp\u003e All new products and systems must be very high efficiency, with the sole exception of tipB1x boilers (open chamber natural draft) which will have a special exemption and can still be manufactured and sold exclusively to be installed in REPLACEMENTS on COLLECTIVE FLUES .\u003c\/p\u003e \u003cp\u003eHeat pumps will have to comply with new minimum limits for noise emissions, while for boilers the noise value will have to be established (without limiting constraints). Furthermore, the circulators mounted on all products must also comply with new minimum efficiency standards (very high efficiency), based on specific EU Regulations (nr. 641\/2009 and nr. 622\/2012). To make the most of all the possibilities offered by the energy label, will it be possible to predict and declare their use in a system already during the conception and development phase of the products? with other devices (e.g. regulation and control), thus proposing an overall more efficient whole, for example. e.g. through the use of renewable sources (solar thermal, geothermal aerothermal energy, biomass). Even so-called or standard products? most sold today - i.e. boilers for gas heating - will undergo an obligatory evolution towards technology with heat recovery from fumes (condensing boiler). We remind you that condensing boilers can recover heat from fumes in a good part of existing systems, even those with radiators, with the use of thermostatic valves now available in various models (also individually programmable on different times), precisely by virtue of their different conception of project that incorporates substantial improvements over previous or standard boilers? such as the new very high efficiency modulating circulators and the combustion volume control in the new premixed burners. Subsequently, for products sold by manufacturers and importers from outside the EU after 26 September 2018, more stringent limits for NOx emissions will come into force\u003c\/p\u003e \u003cp\u003eThe 20\/20\/20 climate-energy package includes ambitious objectives for reducing greenhouse gas emissions, energy consumption as well as increasing the use of renewable energy, corresponding to a percentage of 20% to be achieved by 2020. In this context , the EuropeErP (Energy Related Products) regulation also introduces an energy classification for hot water generators for the purposes of space heating and domestic hot water. This classification translates into an \"energy label\" which must necessarily accompany all the products affected by the Regulation, introduced into the market from 26 September 2015. The labeling constitutes an easy guide for the consumer, who can choose - through standardized and objective indications - the efficient product. In this mode the choice will be the most economical in terms of consumption for the benefit of the user, but also the most virtuous for energy balances and consequently for the environment. The most significant parameters indicated on the label are the seasonal efficiency index in heating and efficiency in the possible production of domestic hot water, according to a scale which in the case of the single boiler product ranges from A to G*. Furthermore, for combined boilers, a load profile is indicated corresponding to the sanitary flow rate of the appliance measured in a series of standard samplings, thereby guaranteeing the declared sanitary efficiency. This index is identified with a letter\/?size? (S, M,¶ÝXXL).\u003c\/p\u003e \u003cp\u003eWarranty\u003c\/p\u003e\n\u003cp\u003e All products for sale on our site are new and packaged. The warranty on this item is 24 months from the date of purchase.\u003c\/p\u003e","brand":"Ferroli","offers":[{"title":"Coaxial Flue Kit","offer_id":47743734939961,"sku":"CALD_323","price":895.0,"currency_code":"EUR","in_stock":false},{"title":"Split Flue Kit","offer_id":47743734972729,"sku":"CALD_3231","price":895.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0847\/7189\/7657\/files\/immagine-1-caldaia-a-gas-ferroli-bluehelix-tech-35c-a-condensazione-metano-completa-di-kit-per-scarico-fumi-erp.jpg?v=1772466101","url":"https:\/\/www.climaconvenienza.it\/en\/products\/caldaia-a-gas-ferroli-bluehelix-tech-35c-a-condensazione-metano-completa-di-kit-per-scarico-fumi-erp","provider":"ClimaConvenienza","version":"1.0","type":"link"}