{"product_id":"mini-chiller-daikin-pompa-di-calore-inverter-aria-acqua-ewya-014dw1p-da-12-8-kw-trifase-r-32-classe-a___","title":"Daikin Mini Chiller Air Water Inverter Heat Pump EWYA-014DW1P 12.8 kW Three Phase R-32 Class A+++","description":"\u003cp\u003e \u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003eFIRST STARTING OPTIONAL, CONTACT YOUR LOCAL SERVICE CENTER!\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003cstrong\u003eTechnical features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\n\u003cli\u003e Model: EWYA014DW1P\u003c\/li\u003e\n\n\u003cli\u003e Power: 12.8 kW\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003cp\u003e \u003cstrong\u003eEnergy efficiency\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\n\u003cli\u003e SEER: 5.71\u003c\/li\u003e\n\n\u003cli\u003e SCOP: 4.70\u003c\/li\u003e\n\n\u003cli\u003e Heating Energy Efficiency Class: A+++\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003cdiv\u003e \u003cstrong\u003ePerformance\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e Cooling Capacity: 12.8 kW\u003c\/li\u003e\n\n\u003cli\u003e Heating Capacity: 12.0 kW\u003c\/li\u003e\n\n\u003cli\u003e Cooling absorption: 4.06 kW\u003c\/li\u003e\n\n\u003cli\u003e Heating absorption: 2.46 kW\u003c\/li\u003e\n\n\u003cli\u003e Air flow rate: 70.4 ~ 85.0 m \u003csup\u003e3\u003c\/sup\u003e \/min\u003c\/li\u003e\n\n\u003cli\u003e Water flow rate: 34.4 l\/min\u003c\/li\u003e\n\n\u003cli\u003e Sound power level: 69 dB(A)\u003c\/li\u003e\n\n\u003cli\u003e Sound pressure level: 50.8 dB(A)\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003cstrong\u003eElectrical Data\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e Power (V,Hz, Ø): 380~415\/50\/3\u003c\/li\u003e\n\n \u003cli\u003eRefrigerant gas: R32\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n \u003cstrong\u003eAir Operation Range\u003c\/strong\u003e\u003cbr\u003e\u003cul\u003e\n\n\u003cli\u003e Cooling: -10° ~ 43°C\u003c\/li\u003e\n\n\u003cli\u003e Heating: -25° ~ 25°C\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cdiv\u003e \u003cstrong\u003eWater Operation Field\u003c\/strong\u003e\n\u003c\/div\u003e\n\n\u003cdiv\u003e\u003cul\u003e\n\n\u003cli\u003e Cooling: -5° ~ 22°C\u003c\/li\u003e\n\n\u003cli\u003e Heating: 9° ~ 60° C\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003c\/div\u003e\n\n\u003cdiv\u003e \u003cstrong\u003eInstallation Data\u003c\/strong\u003e\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\u003cdiv\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e Hydraulic pipe diameter: 25.4 mm (1\") male\u003c\/li\u003e\n\n\u003cli\u003e Pipe connections diameter: 25.4 mm (1\")\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003cstrong\u003eDimensions and weight\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e Dimensions (HxWxD): 1053x1500x650 mm\u003c\/li\u003e\n\n\u003cli\u003e Internal Unit Weight: 164 Kg\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003chr\u003e\n\n\u003cp\u003e \u003cstrong\u003eDaikin \u003ca title=\"Mini Chiller Systems\" href=\"https:\/\/www.climaconvenienza.it\/it\/chiller-pompe-di-calore\/\" target=\"_blank\"\u003eMini Chiller Systems\u003c\/a\u003e\u003c\/strong\u003e \u003cem\u003eSmall chilled or heated water production systems\u003c\/em\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cstrong\u003eWhy the inverter?\u003c\/strong\u003e\u003c\/p\u003e\n\n \u003cp\u003eThe Inverter allows you to continuously modulate the power supplied by the compressor based on the thermal load requests, varying its number of revolutions. This principle, compared to traditional technology which divides the power into discrete steps of even high capacity, guarantees the end customer energy savings and better control of the operating parameters of the system. Most of the time, a building's cooling demand is less than the system's maximum load capacity. The larger the variations in annual load, the more vital it is to ensure that units are operating efficiently.\u003c\/p\u003e\n\n\u003chr\u003e\n\n\u003cp\u003e \u003cstrong\u003eEnergy Savings\u003c\/strong\u003e \u003cem\u003eAbsorption proportional to the power supplied\u003c\/em\u003e\u003c\/p\u003e\n\n \u003cp\u003eThe \u003cstrong\u003eInverter\u003c\/strong\u003e offers, for the chiller as a whole, the possibility of significantly increasing its efficiency at partial loads, i.e. the condition in which, seasonally, the chiller will work most of the time, guaranteeing the best performance and reaching high values average summer seasonal yield ( \u003cstrong\u003eESEER\u003c\/strong\u003e ).\u003c\/p\u003e\n\n\u003cp\u003e Furthermore, with the introduction of the European \u003cstrong\u003eSCOP\u003c\/strong\u003e (seasonal \u003cstrong\u003eCOP\u003c\/strong\u003e ) indicator, the adoption of modulating systems and \u003cstrong\u003einverter technology\u003c\/strong\u003e makes it possible to optimize consumption even in winter, in line with the best requirements required by the new energy index.\u003c\/p\u003e\n\n\u003cp\u003e \u003cstrong\u003eWhat is SEER?\u003c\/strong\u003e\u003c\/p\u003e\n\n \u003cp\u003e'Seasonal Energy Efficiency Ratio' ( \u003cstrong\u003eSEER\u003c\/strong\u003e ) means the seasonal energy efficiency ratio of the unit representative of the entire cooling season, calculated as the reference annual cooling requirement divided by the annual electricity consumption for cooling purposes. \u003c\/p\u003e\n\n\u003cp\u003e\u003cimg style=\"display: block; margin-left: auto; margin-right: auto;\" title=\"ClimaConvenienza.it\" src=\"https:\/\/www.climaconvenienza.it\/pimages\/FCKeditorFiles\/Image\/SEER-.jpg\" alt=\"SEER\" width=\"600\" height=\"422\"\u003e\u003c\/p\u003e\n\n\u003cp\u003e New parameter representing the \u003cstrong\u003eseasonal efficiency of the product\u003c\/strong\u003e . The SEER value is calculated over a period of \u003cstrong\u003e2600 hours\u003c\/strong\u003e of operation during the year. Of these, there are only \u003cstrong\u003e30 hours of operation at full load.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003chr\u003e\n\n\u003cp\u003e \u003cstrong\u003eIdeal Temperature\u003c\/strong\u003e \u003cem\u003eContinuous adjustment of power and noise\u003c\/em\u003e\u003c\/p\u003e\n\n \u003cp\u003eThe ability to work in modulation offers the guarantee of accurate control of the fluid temperature, regulated at a fixed point on the delivery to the system. This feature is ideal from the perspective of industrial application and precision temperature control, as it excludes the constant stops\/starts of the compressors, responsible for electrical and mechanical wear. A further advantage is represented by the lower acoustic impact when compressors and fans operate partially, i.e. in conditions of lower demand for power output, while ensuring greater stability for the water temperature.\u003c\/p\u003e\n\n\u003chr\u003e\n\n\u003cp\u003e \u003cstrong\u003eLower System Costs\u003c\/strong\u003e \u003cem\u003eReduction of system water accumulation\/content (-60%)\u003c\/em\u003e\u003c\/p\u003e\n\n \u003cp\u003eThanks to the ability to react quickly to load variations, chillers that use \u003cstrong\u003eInverter\u003c\/strong\u003e technology can work correctly with a strong reduction in water content in the system (-60% compared to traditional chillers). This allows the thermal inertia to be reduced, with energy optimization and shorter commissioning times. This results in significant savings in system costs as the storage tank is no longer necessary.\u003c\/p\u003e\n\n\u003cp\u003e \u003cstrong\u003eElectrical advantages\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e From an electrical point of view, the \u003cstrong\u003eInverter\u003c\/strong\u003e introduces two great advantages:\u003c\/p\u003e\n\n\u003cp\u003e Low inrush currents, considerably lower than the nominal operating current, on which a lower cost for the supply of electrical components to be installed depends\u003c\/p\u003e\n\n\u003cp\u003e \u003cstrong\u003eMore power available when needed\u003c\/strong\u003e\u003c\/p\u003e\n\n \u003cp\u003eThe \u003cstrong\u003eInverter\u003c\/strong\u003e allows you to vary the power delivered; by powering the compressor at a higher frequency it is possible to reach maximum power values ​​higher than the nominal ones. This offers benefits in getting the system up to speed but, above all, it becomes an evident technical plus when the machine works in extreme operating fields. For example, traditional air-cooled heat pumps are usually combined with boilers to compensate for the efficiency deficit due to cold external temperatures. \u003cstrong\u003eInverter\u003c\/strong\u003e heat pumps can benefit from greater power when the environmental conditions require it, losing only 15% of yield in the transition from 7°C to -10°C of external air (in the case of ON-OFF the reduction would be ~40%), guaranteeing a water temperature of 50°C at all speeds. These advanced heat pumps can therefore be considered \"primary\", since they allow us to avoid the use of boilers.\u003c\/p\u003e\n\n \u003cp\u003e\u003cstrong\u003eCompressors developed and produced by Daikin\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e Daikin has always been at the forefront of the development of compression technology and now offers a complete range of swing, scroll, screw and centrifugal compressors. As a result, Inverter compressor control applies to our entire product range, offering greater comfort and ensuring a more efficient system \u003c\/p\u003e\n\n\u003cp\u003e\u003cimg style=\"display: block; margin-left: auto; margin-right: auto;\" title=\"ClimaConvenienza.it\" src=\"https:\/\/www.climaconvenienza.it\/pimages\/FCKeditorFiles\/Image\/CompressoreSwing.jpg\" alt=\"Compressore Swing\" width=\"600\" height=\"484\"\u003e\u003c\/p\u003e\n\n\u003chr\u003e\n\n\u003cp\u003e \u003cstrong\u003eScroll compressor for capacity control\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e Daikin's compact Scroll compressors are suitable for use with R32 refrigerant, to ensure consistent reliability and high efficiency throughout their useful life. Optimized for use in small and medium power systems, Scroll compressors are combined with air- and water-cooled chillers.\u003c\/p\u003e\n\n\u003cp\u003e \u003cstrong\u003eCharacteristics:\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e › Simple, compact and robust\u003c\/p\u003e\n\n\u003cp\u003e › Absence of valves and oscillating joint mechanisms, to guarantee maximum reliability\u003c\/p\u003e\n\n \u003cp\u003e› Constant compression, to ensure a low level of energy consumption\u003c\/p\u003e\n\n\u003cp\u003e › Greater compression efficiency thanks to the absence of volumetric re-expansion\u003c\/p\u003e\n\n\u003cp\u003e › Low noise\u003c\/p\u003e\n\n\u003cp\u003e › Low starting current\u003c\/p\u003e\n\n\u003chr\u003e\n\n\u003cp\u003e \u003cstrong\u003eAdvantages:\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e › Choosing an R32 product reduces the environmental impact by 68% compared to R410A and directly leads to lower energy consumption thanks to its high energy efficiency\u003c\/p\u003e\n\n\u003cp\u003e › Chiller with Inverter\u003c\/p\u003e\n\n\u003cp\u003e › Hermetically sealed inverter compressor\u003c\/p\u003e\n\n\u003cp\u003e › New outdoor unit covering\u003c\/p\u003e\n\n\u003cp\u003e › Separate MMI-2 controller for internal installation\u003c\/p\u003e\n\n\u003chr\u003e\n\n\u003cp\u003e \u003cstrong\u003eProduct Warranty:\u003c\/strong\u003e All products on sale on our site are new and packaged. The warranty on this item is \u003cstrong\u003e24 months\u003c\/strong\u003e from the date of purchase.\u003c\/p\u003e\n\n\n\u003c\/div\u003e","brand":"Daikin","offers":[{"title":"Default Title","offer_id":47742463017273,"sku":"EWYA-014DW1P","price":5233.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0847\/7189\/7657\/products\/immagine-1-daikin-mini-chiller-daikin-pompa-di-calore-inverter-aria-acqua-ewya-014dw1p-da-128-kw-trifase-r-32-classe-a-jpg.jpg?v=1703186369","url":"https:\/\/www.climaconvenienza.it\/en\/products\/mini-chiller-daikin-pompa-di-calore-inverter-aria-acqua-ewya-014dw1p-da-12-8-kw-trifase-r-32-classe-a___","provider":"ClimaConvenienza","version":"1.0","type":"link"}