{"product_id":"mini-chiller-daikin-pompa-di-calore-inverter-aria-acqua-ewyq009acw1p-da-9-kw-trifase-r-410","title":"Daikin Mini Chiller Air Water Inverter Heat Pump EWYQ009ACW1P 9 kW Three-Phase R-410","description":"\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003eFIRST STARTING OPTIONAL, CONTACT YOUR LOCAL SERVICE CENTER!\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cstrong\u003eTechnical features\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e Model: \u003cspan\u003eEWYQ009ACW1P\u003c\/span\u003e\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003cstrong\u003eEnergy efficiency\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e EER: 2.99\u003c\/li\u003e\n\n\u003cli\u003e ESEER: 4.43\u003c\/li\u003e\n\n\u003cli\u003e COP: 3.29\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cdiv\u003e \u003cstrong\u003ePerformance\u003c\/strong\u003e\n\u003c\/div\u003e\n\n\u003cdiv\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e Cooling Capacity: 9.12 kW\u003c\/li\u003e\n\n\u003cli\u003e Heating Capacity: 10.80 kW\u003c\/li\u003e\n\n\u003cli\u003e Cooling absorption: 3.05 kW\u003c\/li\u003e\n\n\u003cli\u003e Air flow: 5760 m \u003csup\u003e3\u003c\/sup\u003e \/h\u003c\/li\u003e\n\n\u003cli\u003e Cooling Water Flow Rate: 0.430 l\/sec\u003c\/li\u003e\n\n\u003cli\u003e Heating Water Flow Rate: 0.525 l\/sec\u003c\/li\u003e\n\n\u003cli\u003e Nominal head Cooling: 56.4 kPa\u003c\/li\u003e\n\n\u003cli\u003e Nominal heating head: 49.1 kPa\u003c\/li\u003e\n\n\u003cli\u003e Sound power level: 64 dB(A)\u003c\/li\u003e\n\n\u003cli\u003e Sound pressure level: 51 dB(A)\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003cstrong\u003eElectrical Data\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e Compressor type: Scroll\u003c\/li\u003e\n\n\u003cli\u003e Power (V,Hz, Ø): 380~420\/50\/3\u003c\/li\u003e\n\n\u003cli\u003e Refrigerant gas: R-410\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n \u003cstrong\u003eOperation Range\u003c\/strong\u003e\u003cbr\u003e\n\u003cul\u003e\n\n\u003cli\u003e Water side cooling: 5° ~ 22° C\u003c\/li\u003e\n\n\u003cli\u003e Water side heating: 25° ~ 50° C\u003c\/li\u003e\n\n\u003cli\u003e Air side cooling: 10° ~ 46° CBS\u003c\/li\u003e\n\n\u003cli\u003e Air side heating: -15° ~ 35° CBS\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n \u003cdiv\u003e\u003cstrong\u003eInstallation Data\u003c\/strong\u003e\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e Hydraulic pipe connections diameter: 31.75 mm (5\/4\")\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003cstrong\u003eDimensions and weight\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e Dimensions (HxWxD): 1435x1418x382 mm\u003c\/li\u003e\n\n\u003cli\u003e Empty weight: 180 kg\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003chr\u003e\n\n\u003cp\u003e \u003cstrong\u003eDaikin \u003ca title=\"Mini Chiller Systems\" href=\"https:\/\/www.climaconvenienza.it\/it\/chiller-pompe-di-calore\/\" rel=\"noopener\" target=\"_blank\"\u003eMini Chiller Systems\u003c\/a\u003e\u003c\/strong\u003e \u003cem\u003eAir-cooled minichiller with inverter\u003c\/em\u003e\u003c\/p\u003e\n\n \u003cp\u003eThe series of \u003cstrong\u003eDaikin Minichillers\u003c\/strong\u003e dedicated to \u003cstrong\u003eresidential\u003c\/strong\u003e or small \u003cstrong\u003ecommercial\u003c\/strong\u003e applications, with capacities from \u003cstrong\u003e5 kW\u003c\/strong\u003e to \u003cstrong\u003e13 kW\u003c\/strong\u003e nominal, uses the Inverter as a distinctive feature. The \u003cstrong\u003ehermetic Swing compressor\u003c\/strong\u003e for the sizes 005-007 kW and \u003cstrong\u003eScroll\u003c\/strong\u003e for the subsequent 009-013 kW is driven by Inverter as are the unit's fans. High performance is therefore achieved at partial loads, control of the water delivery temperature at a fixed point, which can be exploited, for example, for radiant panel systems, and excellent acoustic performance at partial loads thanks to the simultaneous reduction in noise emission of both the compressor and of fan. The water content necessary for the correct operation of the unit is reduced thanks to the Inverter, and can guarantee operation even without inertial accumulations. The water-refrigerant exchanger has brazed plates\u003c\/p\u003e\n\n\u003chr\u003e\n\n \u003cp\u003e\u003cstrong\u003eWhy the inverter?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e The Inverter allows you to continuously modulate the power supplied by the compressor based on the thermal load requests, varying its number of revolutions. This principle, compared to traditional technology which divides the power into discrete steps of even high capacity, guarantees the end customer energy savings and better control of the operating parameters of the system. Most of the time, a building's cooling demand is less than the system's maximum load capacity. The larger the variations in annual load, the more vital it is to ensure that units are operating efficiently.\u003c\/p\u003e\n\n\u003chr\u003e\n\n\u003cp\u003e \u003cstrong\u003eEnergy Savings\u003c\/strong\u003e \u003cem\u003eAbsorption proportional to the power supplied\u003c\/em\u003e\u003c\/p\u003e\n\n \u003cp\u003eThe \u003cstrong\u003eInverter\u003c\/strong\u003e offers, for the chiller as a whole, the possibility of significantly increasing its efficiency at partial loads, i.e. the condition in which, seasonally, the chiller will work most of the time, guaranteeing the best performance and reaching high values average summer seasonal yield ( \u003cstrong\u003eESEER\u003c\/strong\u003e ).\u003c\/p\u003e\n\n\u003chr\u003e\n\n\u003cp\u003e \u003cstrong\u003eIdeal Temperature\u003c\/strong\u003e \u003cem\u003eContinuous adjustment of power and noise\u003c\/em\u003e\u003c\/p\u003e\n\n \u003cp\u003eThe ability to work in modulation offers the guarantee of accurate control of the fluid temperature, regulated at a fixed point on the delivery to the system. This feature is ideal from the perspective of industrial application and precision temperature control, as it excludes the constant stops\/starts of the compressors, responsible for electrical and mechanical wear. A further advantage is represented by the lower acoustic impact when compressors and fans operate partially, i.e. in conditions of lower demand for power output, while ensuring greater stability for the water temperature.\u003c\/p\u003e\n\n\u003chr\u003e\n\n\u003cp\u003e \u003cstrong\u003eLower System Costs\u003c\/strong\u003e \u003cem\u003eReduction of system water accumulation\/content (-60%)\u003c\/em\u003e\u003c\/p\u003e\n\n \u003cp\u003eThanks to the ability to react quickly to load variations, chillers that use \u003cstrong\u003eInverter\u003c\/strong\u003e technology can work correctly with a strong reduction in water content in the system (-60% compared to traditional chillers). This allows the thermal inertia to be reduced, with energy optimization and shorter commissioning times. This results in significant savings in system costs as the storage tank is no longer necessary.\u003c\/p\u003e\n\n\u003cp\u003e \u003cstrong\u003eElectrical advantages\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e From an electrical point of view, the \u003cstrong\u003eInverter\u003c\/strong\u003e introduces two great advantages:\u003c\/p\u003e\n\n\u003cp\u003e Low inrush currents, considerably lower than the nominal operating current, on which a lower cost for the supply of electrical components to be installed depends\u003c\/p\u003e\n\n\u003cp\u003e \u003cstrong\u003eMore power available when needed\u003c\/strong\u003e\u003c\/p\u003e\n\n \u003cp\u003eThe \u003cstrong\u003eInverter\u003c\/strong\u003e allows you to vary the power supplied; by powering the compressor at a higher frequency it is possible to reach maximum power values ​​higher than the nominal ones. This offers benefits in getting the system up to speed but, above all, it becomes an evident technical plus when the machine works in extreme operating fields. For example, traditional air-cooled heat pumps are usually combined with boilers to compensate for the efficiency deficit due to cold external temperatures. \u003cstrong\u003eInverter\u003c\/strong\u003e heat pumps can benefit from greater power when the environmental conditions require it, losing only 15% of yield in the transition from 7°C to -10°C of external air (in the case of ON-OFF the reduction would be ~40%), guaranteeing a water temperature of 50°C at all speeds. These advanced heat pumps can therefore be considered \"primary\", since they allow us to avoid the use of boilers.\u003c\/p\u003e\n\n\u003chr\u003e\n\n \u003cp\u003e\u003cstrong\u003eScroll compressor\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e Scroll compressors are equipped with two spirals, one remains fixed while the other orbits eccentrically without rotating. Designed for small and medium capacities, they guarantee constant reliability and high efficiency throughout their operational life\u003c\/p\u003e\n\n\u003cp\u003e \u003cstrong\u003eCharacteristics\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e Simple, compact and robust\u003c\/li\u003e\n\n\u003cli\u003e Absence of valves and oscillating joint mechanisms, to guarantee maximum reliability\u003c\/li\u003e\n\n\u003cli\u003e Constant compression, to ensure a low level of energy consumption\u003c\/li\u003e\n\n\u003cli\u003e Greater compression efficiency thanks to the absence of volumetric expansion\u003c\/li\u003e\n\n\u003cli\u003e Low sound level\u003c\/li\u003e\n\n\u003cli\u003e Low starting current\u003c\/li\u003e\n\n\u003cli\u003e The Scroll compressor is suitable for the use of the Inverter, as in the range up to 13 kW, being able to guarantee high ESEER values, absence of peaking and precise control of the outlet water temperature\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003chr\u003e\n\n\u003cp\u003e \u003cstrong\u003eAdvantages:\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e › Extraordinary efficiency at part load\u003c\/p\u003e\n\n \u003cp\u003e› Inverter technology to guarantee low noise and highest ESEER values ​​in the class\u003c\/p\u003e\n\n\u003cp\u003e › Wide operating range\u003c\/p\u003e\n\n\u003cp\u003e › Integrated hydronic systems\u003c\/p\u003e\n\n\u003cp\u003e › Easy “plug and play” installation\u003c\/p\u003e\n\n\u003cp\u003e › Single-phase power for residential applications, three-phase power model available for small commercial applications\u003c\/p\u003e\n\n\u003chr\u003e\n\n\u003cp\u003e \u003cstrong\u003eProduct Warranty:\u003c\/strong\u003e All products on sale on our site are new and packaged. The warranty on this item is \u003cstrong\u003e24 months\u003c\/strong\u003e from the date of purchase.\u003c\/p\u003e\n\n\n\u003c\/div\u003e","brand":"Daikin","offers":[{"title":"Default Title","offer_id":47742577869113,"sku":"EWYQ009ACW1P","price":3415.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0847\/7189\/7657\/products\/immagine-1-daikin-mini-chiller-daikin-pompa-di-calore-inverter-aria-acqua-ewyq009acw1p-da-9-kw-trifase-r-410-jpg.jpg?v=1703188812","url":"https:\/\/www.climaconvenienza.it\/en\/products\/mini-chiller-daikin-pompa-di-calore-inverter-aria-acqua-ewyq009acw1p-da-9-kw-trifase-r-410","provider":"ClimaConvenienza","version":"1.0","type":"link"}